Natch S Pro Fully Automated Nucleic Acid Process System
Natch S Pro Fully Automated Nucleic Acid Process System

Natch S Pro Fully Automated Nucleic Acid Process System

Workflow

Features

Integrated all-in-one platform for seamless workflow

The unified system integrates sample preparation, nucleic acid extraction, and subsequent processing in a single device, eliminating manual transfers and minimizing cross-contamination risks.

1. CO-RE technology for precise pipetting

Unique Compression-induced O-Ring Expansion (CO-RE) technology ensures precise tip at attachment and positioning.

2. Low temperature preservation module to ensure enzymatic activity 

A low temperature module is equipped to prevent the reduction of enzyme activity

3. Independent waste liquid channel to prevent countertop contamination 

The waste liquid channel is designed to work separately from the workstation, ensuring the cleanliness of the laboratory table

4. 96 HEAD, Greatly shorten nucleic acid extraction time

Full board extraction time is reduced to 2hours
Detection efficiency increased to 3.5h to complete 96 tests

5. One-click automatic operation, no need to be on duty throughout the process

Interface operation is simplified, and the whole process of nucleic acid extraction can be automatically completed with one click

Specifications

Instrument Model S-S14D
Sample Type Serum, plasma, Whole blood
Technology Platforms Advanced magnetic beads technology
Sample Throughput 576 tests/batch
Detection Time Pooling test: 576 tests/4.5 hours;  Individual test: 96 tests/3.5 hours
Sample Tube Spec. Compatible with original sample tubes of all sizes
Pipetting Range 0.5-1000μL
Pipetting Performance Pipetting volume 10μL, CV≤5%; 100μL, CV≤2%; 1000μL, CV≤1.5%
Pipetting Channel 8 independent channels, with dual liquid level detection, clot detection, air tightness detection, tip detection, dynamic positioning and other functions.
Liquid Level Detection Dual detection technology of pressure and capacitance can identify and record abnormal suction and discharge process (empty suction, missing suction, less suction, clot blockage)
Extraction Principle Pipetting, side magnetism
Magnetic Field Control Permanent magnet mode, three-dimensional surround magnetic attraction technology
Tips Loading and Uploading CO-RE technology automatic tip loading and uploading
Temperature Control Range Low temperature module: 0-15℃ adjustable
Heating module: 5-105℃ adjustable
Anti-contamination System UV lamp function, independent waste liquid channel
Barcode Scanning Sample automatic scanning and sampling system (supports multiple barcodes), scanning time ≤ 1s
Software System Window 7, Window 10 (recommended)
Interface Type USB interface, RS232C serial port, support LIS system
Operating Environment Temperature: 15-30 ℃
Humidity: 15%-85% (indoor, no condensation)
Weight and Size About 220Kg, 2619mm(L)*903mm(H)*1043.5mm(W)
Power Supply Voltage: 115VAC/230VAC, ±10%
Frequency: 50/60Hz
Certification NMPA

 